Does Vaseline Help With Bruises, Articles A

Error Code 61, 611, Four times Problem: Fan motor fault. This is the error code for ignition failure. This error code may appear when you power up the unit. d. Igniter activates. Smith INTELLI-VENT Page 1 INTELLI-VENT CONTROL INFORMATION When Used On Gas, Residential, Power Vented Water Heaters Printed in the USA - 0605 Part No. 12-Year limited residential warranty gives you peace of mind. Some of the problems are common, and they do not include an error code: Water is not hot enough or is too hot The temperature of the exiting water fluctuates Noise Burner does not ignite Long time to get hot water Sediment buildup Learn more, Facebook II Twitter II Pinterest II Linkedin. Once you confirm the issue, turn off the gas control knob. Your AO Smith Water Heater's status light will blink 5 times every three seconds if the temperature sensor gets defective. To fix this issue, you should replace this part. The tools needed to solve the problems from below are mainly the screwdriver, manometer, and multi-meter. } Related Pages:pool heater repair nearby, water heater repair cost, home pool heater service, water heater fix near me, pool heater installation near me. As long as you see this error code, you must turn off the water heater first. You May Find Interesting: Rheem Gladiator Solid Red Light. You may type any combination of product name, family, size, model number, etc. If people see this error code, they have to be more aware because it is the warning for the 991 error code. Products: Water Heaters . So, replace the sensor to clear the faulty code. A little more information.sometimes when I shut off power at the breaker, let is sit for a while and then turn the power back on, it will do it's diagnostic cycle (blinking green light) and then start flashing red (2 times). It sounds like the main control is malfunctioning, what's the complete model number of this water heater? Secondly, you must replace the gas control valve if the pilot valve gets stuck in an open position. Keep in mind that the error codes are shown differently if the units are connected through the Easy-Link System it can be seen what the error code is and which unit has it. The repair guide covers indoor, outdoor, condensing, non-condensing, and ultra-low NOx water heaters with on-demand technology. AO Smith ES12-50R55DV (50 gallon) electric hot water tank. FIX: Debris on the thermistor, loose or broken wire connection. The cookie is used to store the user consent for the cookies in the category "Performance". You also have the option to opt-out of these cookies. Solution: Check if the remote controller is of the right type, also connections between the water heater and remote. View All Tankless Models with X3 Learn About Tankless with X3 Scale Prevention Technology This is an in-depth guide on AO Smith Water Heater Troubleshooting Codes. Why is my AO Smith water heater stopped working? Follow the below steps to erase those error codes from the display: If the error codes return, you must replace the thermistor. And this tutorial will help in replacing the thermocouple on the AO Smith Water Heater: Secondly, inspect the wire connectors for loose. Get information and support for all A. O. Smith models. Before doing so, dont forget to check the wiring attached to the control board. To have the unit working properly, it has to be supplied with the power and correct connection. Smith with Intelli-vent device. advanced settings. You can either left-click on the link to open the manual in a new tab or right-click and save a copy directly on your computer. So not happy that I had to replace it, but very happy with AO Smith that they honored the warranty. Like other heat pump water heaters, AO Smith Heat Pump Water Heater uses the ECC or transformative solid state technology to reduce the energy usage. This chapter will discuss everything you need to know about the flashing light codes on AO Smith Water Heater. Empty all the water that has accumulated in the exchanger properly. The status light flashes 1 times with a three-second pause indicating your water heater operates at its tip-top condition. CODE: 70, 701, One timePROBLEM: Problem with the computer board. A.O. Just shut off the electric supply to the unit. How long does an A.O. Our comprehensive A.O. Then, relight the pilot by following the lighting instructions I mentioned in the previous chapter. The average US household uses 64.3 gallons of hot water each day. To solve this problem, you will need to find the correct settings for your water heaters model and reset them on the computer board. Basically, both 2-chamber and 4-chamber models will pop up with those error codes. Now, wait for 10 minutes to let the thermopile cool down. Next, check for water leaks and fix them if needed. Drain your water heater. Common symptoms, problems, and fixing tips. Use the pipe wrench to tighten the fittings. This error code is another thermistor failure but this time, it is referring to the mixing or mix thermistor. Examine the thermal regulator to see whether it is offering a proper performance or not. However, I highly recommend you call a certified plumber to solve this issue. FIX: Check for the proper settings on the computer board. I checked all the wires and didn't find any problems, frayed insulation, etc. We don't tend to provide any plumbing advice or any advice that should come from a certified professional. I have tested the power at the thermostat and the elements with a multi meter and they all check out fine. Related Troubleshooting Pages:A.O. If it doesnt throw a trouble code, make no beeping, or flashing light, and understand the water is functioning properly. An example of data being processed may be a unique identifier stored in a cookie. Check if there is a gas leak. Alarm reads E05 and a lot of water is going thru the overflow drain pipe It's still under warranty. This is usually caused by scale build up which locks the motor drive. Clean away any dirt or debris and check the quality of the connection wires. He obtained his Bachelor of Science degree from the University Of Texas at El Paso. Related Error Code Pages:A.O. However, damage and soot can sometimes prevent the AFR rod from doing its job properly and it requires attention. Dont need to worry about it. These cookies will be stored in your browser only with your consent. Instruction Manual - High quality water heaters and water treatment . They also have to make sure that the flame rod does not come with soot. Our product specs, warranty sheets, installation guides, and user manuals are online. However, there is no need to be panicked because they have the solution for this circumstance. Press down the gas control knob all the way in while depressing the igniter button continuously. FIX: See error codes 111 and 121. Also, you should check the computer board for any sign of burn marks too. How to use diagnostic system and fix the problems using the error codes that appear on the remote controller. } What does a thermal regulator do on a pool heater? So, the corrective action you need to take is- check the thermopile and replace it if it gets defective. Another sign that this is the issue is if the error code is blinking five times. FREE Estimates! Then, disconnect the thermistor and reconnect it. This chapter will describe the meaning of a specific error message your AO Smith Electric Tankless Water Heater throws. Before you start to disassemble your water heater, remember to shut off its power and that you reassemble it correctly. FIX: Check is the Hi-limit switch properly functioning that there is no loose or broken wire connections, no soot on the flame rod or damaged computer board. Related Price Pages:A.O. Revision 2 includes updated troubleshooting information for error codes 3, 4, and 6. No, it's not. how to fix the Pentair heater error codes problem, Rheem Tankless Water Heater Maintenance [Why+ How To Do], Rheem Tankless Water Heater Code 61 [Why+ How To Fix], Rheem Tankless Water Heater Code 14 [Why+ How To Fix], Rheem Tankless Water Heater Code 99 [Why+ How To Fix], Rheem Tankless Water Heater Code 76 [Why+ How To Fix]. Second, turn on a hot water faucet anywhere in your house to let the air out of the waterline. Firstly, the thermopile is at fault. In contrast, 4 consecutive flashes with a 3-second pause indicates the temperature sensor of the unit senses the water temperature is too high. Before developing Water Heater Hub, Anthony Barnes was a full-time plumber, and he has undertaken a wide variety of projects over the decades. The red high limit button is NOT tripped. Afterward, install a new thermistor. Examine the water pipes and make sure that they are clean. And then, use the wrench to secure the thermistor properly. FIX: Check the connections between water heaters. The showers in homes built after 1992 typically have a flow rate of 2.1 Gallons Per Minute. We will get back to you as soon as possible with the best possible answer. GCVL40-200 GCVL40-201 GNR40100 GNR50100 GPS-75 GPVH40100. F05 - E02 - Door lock fault F08 - E01 - Waterfill fault I've looked up the error codes for these, and am just getting started diagnosing the issue. Second, the thermopile of your gas water heater has not reached its operating temperature yet. Next, use the -inch open-end wrench and pull out the thermistor by turning it counter-clockwise. You can do a few basic checks first like making sure there are no loose wire connections or soot on the flame rod. Afterward, put everything back into its place. I turned off for 5 minutes then back on. AO Smith tankless water heaters equipped with the remote controller have a great advantage; a self-diagnosing function that helps in diagnosing the heating problem. Either the thermopile doesnt cool down quickly or the pilot valve is stuck in an open position. I highly recommend you use a multimeter to test the continuity of them and replace them if needed. Ever. Remove the upper access panel by using a flathead screwdriver. If there are any burn marks on the computer board then this is a sign that your water heaters computer board is overheating and cutting out. Once I did that and cleaned out the sediment, I had an e02 error code on the panel. Ok, yes I really don't know, I rarely service these newer water heaters, so your best bet is to Contact AO Smith again to see what's going on. FIX: Check for connection/breakage of wires, corrosion or frozen connectors, fan motor covered with the dust, burn marks on the computer board. A.O. If you own an AO Smith tankless water heater, then its important that you know how it works and what to do when things go wrong. Ignition failure is not an uncommon issue with water heaters and boilers, but its also highly recommended that you solve this issue by calling a technician to your home. Yes, you can fix the error codes on the Pentair heater by identifying the issue and its solution. There are actually many types of thermistors in your water heater and thus, any error codes that relate to problems they are facing. COPYRIGHT 2023. Continue with Recommended Cookies. 7+ Common AO Smith Water Heater Troubleshooting Codes. FIX: Is the water heater set for the right elevation? Continue with Recommended Cookies. I don't think I should have yo pay anyone. Solution: Check for connection/breakage of wires, corrosion or frozen connectors, fan motor covered with dust, burn marks on the computer board. They should be able to tell you the correct dipswitch settings for your model so you can correct it yourself. The only solution to clear those error messages is to replace the thermistor. Alternatively, the error code will flash four times. If you own a 540 model AO Smith tankless water heater, then this is an error code that may appear on your display screen. You should also ensure they are securely attached. If there is air in the waterline, your water heater may throw this erratic code. Models from the 240, 340, and 540 series will show the error codes on both temperature controller and remote controller. Then, leave the unit for 10 minutes to let the thermopile cool down. Dont forget to use Teflon tape on the gas piping connections and fitting on the back of the gas valve that screws into the tank. Need sanity check to make sure I troubleshoot the device properly: Problem: No ignition. View more. To determine if the heating element is shorted out, plug in a multimeter and test if the element, itself, is shorted. The Pentair heater e05 error code is one of the 12 error codes for this pool heater. Fortunately, I broke down how you can replace the thermistor correctly in this section: Ao Smith Electric Water Heater Error Code E10-E13. If the condensate drain is not properly installed on the vent collar of the water heater, then there could be water in the internal combustion engine. Problem: Warning for the "991" error code. Clean the sensor along with the terminals and put it back in place. CODE: 10 (101), Five timesPROBLEM: Warning for the "991" error code. We will also tell you the solutions that will help you to fix the problem. Using Rheem error codes to troubleshoot Rheem tankless water heaters. Solution: Check for the proper settings on the computer board. CODE: 03 (031), One time PROBLEM: Incorrect dipswitch settings. Your AO Smith Water Heater will flash the error code E03 if there is a low water level in the heater. Our comprehensive A.O. Low water flow and loose wiring also contribute to the Pentair Mastertemp e05 code. Electronic User Interface allows you to easily set temperature, operating mode, and child safety lock feature. to control or estimate. So, keep reading. 01 Pressure Switch Fail On, should be Off 11 Pressure Switch Fail Off, should be On 02 Ignition Fail after 3 attempts 04 ECO Open 05 Temperature Probe Open 15 Temperature Out of Bounds < 30 degrees 25 Temperature Out of Bounds > 220 degrees The following Error Codes are internal to the controller. This represents our closest approximation of your likely experience with this water heater using National Averages, but actual performance may vary depending on factors beyond our ability I recommend the factory setting or default of 120F (49C). How to tell if the AO smith water heater is working? Error code E02 on AO Smith Electric Tankless Water Heater indicates that the unit determines the heated water exceeds the temperature limit. The cookie is used to store the user consent for the cookies in the category "Other. First off, turn the electric supply off to your water heater at the circuit breaker. You can see those error codes only on an AO Smith Water Heater with two or four chambers. If you have either a 2-chamber or 4-chamber model of AO Smith Water Heater, you can see the trouble codes E20, E21, E22, E23, and E24 for a single reason. Smith Water Heater Manuals Anthony Barnes July 23, 2018 Need to Hire a Plumber? In other words, when the sensor senses the water temperature is too high, it will throw this error code. This is the error code for ignition failure. How To Fix: First off, turn the gas control knob to the off position. To fix this issue, you should replace the control board. CODE: 03 (031), One timePROBLEM: Incorrect dipswitch settings. c. The computer checks for any problems with the unit before startup. Now, back the electric power to your water heater and it will clear those faulty codes. Smith Water Heater, look no further! How do I reset my A.O. I eventually called an electrician, who said it seemed to be a short at the top of the tank where the wires for the power and smart module are. FIX: Check is there a loose or breakage in wire connection or debris on the thermistor. The Pentair error code E05 indicates an open stack flue sensor. From https://www.justanswer.com/ythiJustAnswer Customer from San Antonio, TX: AO Smith 50 gallon electric water heater giving error code e55 for water leak d. Solution: Connections or breakage of wires of the flow adjustment valve, scale buildup on the motor drive which gets locked, water leakage. I In a 6-flat/3 story building with 6 apartments/total of 15-16 residents, I have an AO Smith water heater/25 yrs old with specifications of 81 gall capacity, 149 gall/hr recovery, 154,000 BTU. Save my name, email, and website in this browser for the next time I comment. The initial setting is 120F, but you're in control after installation. Solution: Before AO Smith tankless water heater troubleshooting, test the hi-limit switch and confirm it is working fine and the wire connections are not loose and broken. If the error code returns, I bet the sensor is at fault. groundwater temperature for your location, and residential energy prices as reported by the Department of Energy. A.O. For a better experience, please enable JavaScript in your browser before proceeding. 4.6. Finally, turn the power back to the unit and it will clear the error code. Eric Alvarez is an HVAC guy based in El Paso, Texas, United States. These are The Easy Steps, The sound of the door squeaking is certainly very, You may want to remove broken drills from wood when, Spray paint is an aerosol paint that is used by, The toilet flange heightis important for proper, After you receive your new washing machine, you are, Most people take it for granted that their, Like most people, you probably take your air, Copyright 2022 Burnshomeconstruction.com. Toggle navigation. Look for the blockage in the vent system and ensure if the distance between the intake and exhaust is not too small. Analytical cookies are used to understand how visitors interact with the website. BFC Cyclone Twister II document.write(intYear); Solution: Check for blockage in the vents, the distance between the intake and exhaust terminals is per instructions, and remove if there is grease or dirt in the gas burner and fan motor. The cookie is set by GDPR cookie consent to record the user consent for the cookies in the category "Functional". Adjust the valves on the main line to set the water pressure at the right level. Problem: Miscommunication between the water heater and remote controller. Smith Water Heater Troubleshooting. This error code indicates that there is a problem with the flow sensor on your AO smith tankless water heater. Smith Water Heater Repairs. He obtained his Bachelor of Science degree from the University Of Texas at El Paso. Clean your AFR rod of any soot, and check for any damage or loose connections to see if you need to find a replacement. Get Help from a Local Plumber. Necessary cookies are absolutely essential for the website to function properly. The Fire The fire needed to heat the water also poses a danger if the water heater does not put properly. AO Smith Water Heater Error Code E02 [5 Easy Fixes] 1. And it will also cause the display of error code E05. See Figure 4. Manage Settings This error code is closely related to the error code 11 (111) as it is a sign that your water heater is losing its flame. FIX: Check if the remote controller is the right type, also connections between the water heater and remote. AFR rods monitor the air fuel ratio of your water heaters internal combustion engine, which is a massively important part of your water heaters function. Smith - Troubleshooting help - Hello my frist post here. This debris will be what is preventing your water heater from functioning properly. Smith Show 161 Results Brand: A.O. Conduct checks on all the parts and sensors on a regular basis. Verify the O-ring is in its place. You can now use this knowledge to help diagnose and fix problems with your AO Smith tankless water heater so you can continue enjoying hot water with little fuss! Alternatively, you can watch this video that will come in handy: AO Smith Water Heater Status Light will flash 8 times every 3 seconds if the gas control valve is in the off position but the thermopile still produces electric power. {{INUSING}}, The average cost per Gallon is ${{PROPANEGASPRICE}} To view or adjust our assumptions of the most common factors that impact this products performance using National Averages, please view the